Section 918
EI MVP-50P
918 - 4 Page Date: 29. September 2014
Pilot´s Operating Handbook
EXTRA 330LX
FUEL PRESSURE INDICATOR
green range 0 psig - 14 psig
red line 14 psig
918.3 EMERGENCY PROCEDURES
Not affected.
918.4 NORMAL PROCEDURES
Magneto Check
- Check the magnetos at 1800 RPM. Allowed drop is 175 RPM
(max. difference 50 RPM).
- Check Alternator Output.
- Move also the propeller control through its complete range to check operation and
return to full "HIGH RPM" position.
Turn boost pump "ON" (check indicator movement on the fuel flow gauge).